  #11  
Old 03-19-2023, 03:59 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

And now, if I put the Process card in, and hook the interface to it, it works.
It’s like the slot order is backwards on this computer!
In system usage, it’s showing everything backwards.
But in DigiTest, it shows in the correct order!
I have two of these computers and the same thing happens.

My next test is reverse all the cards and see if it will all still works!
Reply With Quote
  #12  
Old 03-19-2023, 04:36 PM
JFreak's Avatar
JFreak JFreak is offline
Moderator
 
Join Date: Jan 2003
Location: Tampere, Finland
Posts: 24,853
Default Re: 192 isn’t being seen.

Quote:
Originally Posted by milesofwire View Post
It’s like the slot order is backwards on this computer!
You have ribbon cables connected the wrong way. Without reading the manual the intuitive way would be connecting core card A to accel card B, but it is the other way around. A is input and B is output, and don't ask me why the cards don't read in and out. So, core B to accel A and accel B to process A
__________________
Janne
What we do in life, echoes in eternity.
Reply With Quote
  #13  
Old 03-19-2023, 04:52 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

That did it, apparently there is a reversal of slot order allocation in Pro Tools 8.
Putting the cards in reverse order makes the system function normally.
DigiTest passes, just looks weird being backwards.
System usage window shows everything in proper order.
I can’t be the only one who’s figured this out the hard way.
Reply With Quote
  #14  
Old 03-19-2023, 04:57 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

Quote:
Originally Posted by JFreak View Post
You have ribbon cables connected the wrong way. Without reading the manual the intuitive way would be connecting core card A to accel card B, but it is the other way around. A is input and B is output, and don't ask me why the cards don't read in and out. So, core B to accel A and accel B to process A
But it works. There is no other way with this setup.
PT 8 supported PPC mac, and I’m putting it in to one!
Obviously the ribbon connectors are pass-thru.
Or possibly I have a Mac and HD cards that are from a reversed alternate reality!
Reply With Quote
  #15  
Old 03-19-2023, 05:12 PM
JFreak's Avatar
JFreak JFreak is offline
Moderator
 
Join Date: Jan 2003
Location: Tampere, Finland
Posts: 24,853
Default Re: 192 isn’t being seen.

Yes, if you have ribbons reversed, then the "first" card would be "last" that you would expect.
__________________
Janne
What we do in life, echoes in eternity.
Reply With Quote
  #16  
Old 03-19-2023, 05:30 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

Quote:
Originally Posted by JFreak View Post
You have ribbon cables connected the wrong way. Without reading the manual the intuitive way would be connecting core card A to accel card B, but it is the other way around. A is input and B is output, and don't ask me why the cards don't read in and out. So, core B to accel A and accel B to process A
Yes, a simple IN / OUT would help.
I sure I’m not the only newb with HD that’s done this!
The ribbons I have are trained that way when I got them.

Last edited by milesofwire; 03-19-2023 at 05:40 PM.
Reply With Quote
  #17  
Old 03-19-2023, 05:37 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

Quote:
Originally Posted by JFreak View Post
You have ribbon cables connected the wrong way. Without reading the manual the intuitive way would be connecting core card A to accel card B, but it is the other way around. A is input and B is output, and don't ask me why the cards don't read in and out. So, core B to accel A and accel B to process A
Oh! I see said the blind man! Got it!
Apparently the person that had these cards before me was making the same mistake!
Ok then, I’ll put it together that way!
Thanks
Reply With Quote
  #18  
Old 03-19-2023, 07:10 PM
milesofwire milesofwire is offline
Member
 
Join Date: Oct 2001
Location: California
Posts: 503
Default Re: 192 isn’t being seen.

Really appreciate the help JFreak! That was it!
It’s really confusing when the plugs are lettered A for in and B for out.
I just assumed that the first plug would be “A” then to “B”.
And since my ribbon cables were perfectly formed to do just that, I automatically just went with it.
Reply With Quote
  #19  
Old 03-19-2023, 08:00 PM
JFreak's Avatar
JFreak JFreak is offline
Moderator
 
Join Date: Jan 2003
Location: Tampere, Finland
Posts: 24,853
Default Re: 192 isn’t being seen.

No problem. Note to Avid: next time you design a confusion like this, there would be easy way out.
__________________
Janne
What we do in life, echoes in eternity.
Reply With Quote
Reply

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -7. The time now is 03:32 AM.


Powered by: vBulletin, Copyright ©2000 - 2008, Jelsoft Enterprises Limited. Forum Hosted By: URLJet.com