Default Re: Session setup logic issues with Sync X

Quote:
Originally Posted by LukeHoward View Post
Also, a cosmetic bug: Hardware Setup displays the Clock Master sometimes as SYNC HD instead of Sync X.
This appears to happen after changing the sample rate from Hardware Setup (with no session open). After the SR change, the Sync X is removed from the list of clock sources, the previous SR is displayed on the Sync X front panel, and the MTRX fails to lock: it receives the SR change via DigiLink but the WC is at the old rate. (The HD I/O, on Loop Sync, locks to the correct sample rate immediately.)

After closing Hardware Setup, the correct SR is displayed on the Sync X front panel, and the MTRX is locked.

When reopening Hardware Setup, the Clock and Loop Master are displayed as SYNC HD (rather than Sync X).