Default Re: SyncHD - adding in MTRX; removing HD I/Os

Quote:
Originally Posted by ScottyD View Post
I'm in the research phase of rebuilding our Pro Tools rooms and would like some guidance on the best way to transition from our current build with a Sync HD and 2 HD IOs to just the Sync HD with a MTRX IO that replaces the HD IOs.

Our current setup uses Loop Sync from the Sync HD to the first HD IO, then to the 2nd HD IO and then finally loops back into the Sync HD. Each HD IO also has WC from a Drawmer D-Clock. This same D-Clock feeds the Sync HD. The Sync HD also has Vid Ref and LTC input.

I'm assuming since the MTRX only has WC/VBB in and out, I'd use this for the Loop Sync. Then remove the existing WC cables coming from the Drawmer. Does this configuration work?

Thx in advance,
Scotty D
I would lose the Drawmer, and connect either the WC or Loop Sync output of the Sync HD to the MTRX. In this case (if the Sync HD is always loop master), it won't make any difference, the MTRX can handle base rate WC (which is what Loop Sync effectively is). You need to configure the MTRX clock source appropriately in DADman, too.