View Single Post
  #2  
Old 04-03-2011, 06:08 PM
Top Jimmy's Avatar
Top Jimmy Top Jimmy is offline
Moderator
 
Join Date: Oct 2005
Location: Spokane, WA
Posts: 5,932
Default Re: Sampling Theorem/Nyquist

Quote:
Originally Posted by ctoptrophobe View Post
Is it based on the file size reduction or the file duration?
Neither.

First off, there's something fishy about the file sizes. If they are both 44.1/16, then the 14 sec file should be bigger.

After sample-rate converting to 22.05 kHz., the new Nyquist is 11.025 kHz. The anti-aliasing filter should have removed any content above that so the file that originally had more content above 11.025 kHz is the one that is more adversely affected.

So, what tones or content is in the two files?
__________________
James Cadwallader

Mac Studio, 64GB RAM, 1 TB SSD, Glyph 2TB USB3 HDD, OWC drive dock, Mac OS Monterey 12.6.8

Pro Tools Ultimate 2023.9, HD Native, Focusrite Red 8Pre

Presonus Faderport, Pro Tools | Control
Reply With Quote