Re: Network periodic transmit error
There are many things that can cause a network error, so each issue/system should be treated independently. It's not a single bug.
- Older MTMs (with M10 or M40 written between the softkeys) have to be connected to Ethernet port 1 on the back as port 2 has known hardware issues.How to change ports
- Network hardware, from the cables, switches, passthrough connector in the S6, and settings in a non-Avid supplied switch/router,
- EUCON only supports EUCON, Dolby Metadata and Satellite on its network, no Audio over Ethernet, Web or Network Storage.
- Check other network ports on the Workstation, make sure that they are not in the same subnet. IE. the first 3 numbers in the IP address are not the same x.x.x.0
- If the Workstation CPU/memory/network is overloaded, it will cause these issues
- If the PT session is overloading PT it will cause these issues.
- PT/EUCON 21.10 onwards removes a lot of the PT overloading/EUCON performance issues.
|