HDIO WC issue in latest PT2020 - MTRX
A recent update in protools and DADMan has seemed to have put my HDIO into a bad place. Essentially I cannot get it to clock so I get oscillating drop outs at varied rates depending on what clock source is selected.
I have a fairly complex setup with a MTRX, Burl B80, HDIO, Waves DLS. These all get WC from a OCXHD. I noticed new options for the MTRX in both DADMan and PT. IE, in setup you can now select MTRX as the sync source in PT. There is now a DLY option in DadMon that seems to set itself to 5 no matter what I do.
I have tried every config I can think of and the closest I have gotten to where the HDIO seems to sync is with the DLS off. When I start PT it will not sync. I go to settings and select the HDIO WC as source and it works, then I go and reset to MTRX and it continues to work as long as the session is up and running.
The system was working fine until some recent update. I don't always use the HDIO so may not have noticed it when it really started.
MTRX is set to WC in, Pri/Pri, Adapt to Digilink1, 75ohm term
Session is at 96K, have not tried any others yet.
Any thoughts?
HDX2
Mac Trashcan
S6
|