View Single Post
  #6  
Old 10-24-2022, 02:49 PM
EddieJones's Avatar
EddieJones EddieJones is offline
Avid
 
Join Date: Dec 2014
Location: Santa Cruz
Posts: 4,593
Default Re: Connection problems/IP issues? with Avid Control and Avid Dock

Quote:
Originally Posted by Voldemort View Post
Hi,
MY PROBLEM:
When giving static IP to DX32 connection, DADMAN seems to work perfectly. Good. I used 192.168.3.1.

I gave the switch on USB LAN 2 (with Dock and iPad connected) DHCP.

Suddenly everything worked. I checked IP settings in Mac Network panel (USB LAN 2 = 169.254.183.147 (subnet 255.255.0)). In EUControl, Dock was assigned with 169.254.175.48:49168 and iPad/Avid Control with 169.254.51.16:588379.

Then I started to program a soft key on Avid Dock in EUControl. I returned to Pro Tools to test the key, which didnt work. Then I noticed that Avid Control was «blank» - the not connected to eucon icon was not visible … but no info and no response from actions in DADMAN.

I restarted an hoped for the best … not working. Dock and iPad visible in eucon my surfaces, but no response/monitor profile from DADMAN (monitor profile assigned in eucon). Checked Macs network panel, the switch on USB LAN 2, had a new IP: 169.254.165.78 (yesterday 168.254.183.147), but in EUControl, the Dock and the iPad had the exact same IPs as before the restart …

Sorry for the long post … Is this perhaps my problem? The switch and IP issues?
Does anybody know what I am doing wrong?
I think your setup is OK. But have questions.

For DADMan I presume you set a Static IP at both ends(the Mac adapter and MTRX. 192.168.3.1 and ?
Does DADMAn still control the MTRX when EUCON doesnt?
Are you saying you see the Dock and AC in EuControl? In the All Surfaces and My Surfaces lists?
Did you do a migration to this computer?
Reply With Quote