Thread: to DIGI staff
View Single Post
  #2  
Old 01-24-2003, 07:43 AM
Rob Macomber Rob Macomber is offline
Member
 
Join Date: Feb 1999
Location: NY, NY, USA
Posts: 404
Default Re: to DIGI staff

Run LTC from VTR to USD LTC IN. Then USD LTC out to the TC DAT. Slave PT to the VTR as usual. the USD refreshes TC and sends to DAT. If the DAT is not referenced to VID REF...then run Word clock out of USD ( which is VID REF'd) to word clock in on DAT.

Or simply locking the clock of the DAT to AES input would lock all clocks. ( assuming the USD and VTR are referenced alike)... but ...it would be better to have a seperate dedicated line for clocking.

Rob