View Single Post
  #2  
Old 02-17-2023, 05:55 PM
Ben Jenssen's Avatar
Ben Jenssen Ben Jenssen is offline
Member
 
Join Date: May 2000
Location: Oslo
Posts: 5,260
Default Re: clocking doesn't match sample rate

I've been there a couple of times, although it was years ago, but it's not very complicated. Basically you create a session with the sample rate it was clocked with, and import the audio files and deselect 'convert sample rate'. So even though they are 'stamped' 44.1, and you know they are effectively 48, they will play back correctly in the 48kHz session.

I don't know of any way to 'repair' the session. It might be possible, but this import trick is what I know.

If it's a session full of tracks with scattered clips, I guess you could consolidate all tracks from 0.000.00 in the session with the wrong speed, then do the import trick.
__________________
Mac mini M2 16GB RAM macOS 13.4.1. PT Studio 2023.6.
Topping E30 II DAC, Dynaudio BM6, 2 x Artist Mix, SSL UC1, Control on iPad.
Reply With Quote