View Single Post
  #6  
Old 11-15-2018, 11:27 AM
EddieJones's Avatar
EddieJones EddieJones is online now
Avid
 
Join Date: Dec 2014
Location: Santa Cruz
Posts: 4,597
Default Re: Euphonix MA 703 (clocking) problem

This is most likely the crystal(s). We usually replace both when we're in there.

You should measure the +/- 18Vdc rails. They should be between 17.5-18Vdc. Attached is a picture. In this picture, the 3 test-points can be seen just under the serial number label, just to the right of the black heatsinks. They're labelled +18, GND, and -18.

The pictured board is a newer version with the regulators heatsinked, the older versions have the regulators lay flat, soldered to the board.

The crystals are custom-made by Cal Crystal Comclock. High-precision. We have some we could sell you.
Attached Images
File Type: jpg crystals.jpg (55.0 KB, 0 views)
Reply With Quote