Re: Venue Tips & Tricks
Great idea Dave,
I'll add a few...
Using the Default Button
Press and hold the Default button (or ALT key on the keyboard) to reset any parameter, or parameter section.
Examples
Deafult + SELECT resets a fader to 0 dB (great for VCAs!)
Default + EQ IN/COMP IN/GATE IN resets the entire EQ/Comp/Gate section
Default + <any encoder> resets that individual parameter (great for resetting a single band of EQ)
Keyboard Equivalents
In many cases the modifier buttons on the D-Show surface can be used to invoke keyboard shortcuts. This is especially helpful when managing snapshot or plug-in lists, for example.
Multi-Select = SHIFT
Default = ALT
Fine = CTRL
Hardware Monitoring
D-Show 1.1 features an integrated hardware monitor that keeps track of all voltages and temperatures for the FOH Rack motherboard, and automatically alerts the user to out of range conditions. To display the hardware monitor at any time, press CTRL+SHIFT+M.
|