Default Displaying Preamp Controls on Process Module Encoder

With MTRX or any other PRE-compatible remote controllable mic preamps, add microphone Gain control to the process module encoder by holding down the Back (arrow) button at the bottom of the process module while pressing the Input switch. The encoder should turn Red. Bank using the adjacent arrow switches to get to the Gain parameter. As a shortcut, engage the ALL switch from the Master Module before performing this sequence to change the process module encoders on all channels. Experiment by bringing other parameters to the process module encoder such as Threshold on DYN, Sends or HPF frequency for EQ.