Default Re: changing sample rate or clock source on MTRX popping monitors

Quote:
Originally Posted by jgaz View Post
Has anyone else experienced this? Even with the control room monitors cut and volume pulled down to -100%, my monitors are popping when I change the sample rate or clock source in DADman.

Thanks,

Jeff
I do not have this issue, if that helps for comparison.

All digital will pop when changing sample rates but cutting the monitors doesn't pass the pop to to the speakers. Cut is a complete mute.

However, I'm curious what your monitors are. Are they hooked by digital/AES? In which case the sample rate change will effect them (because your monitors will be asynchronously re-clocking too.) That would be expected unless your monitors have a function to automute when reclocking.

Mine are connected via analogue, for reference.
__________________
Pro Tools Ult 2024.3.1, HDX 2, MTRX/SPQ, RME BBF Pro + MADIface ProS1 x 2, Fire Max11 x 2, Dock, iPad Air5 Mac Mini 14,12, 12 core, macOS 13.6.6RAM 32GB, SSD 4TB, GPU 19 coreQNAP TVS-872XT 148TB TB3