Dwight

Where do you recognize the chattering from on the 442 interface? If it's coming from the power switch area or where the 442 logo is silk screened on then it would point to a power supply issue. If it's coming from the XLR inputs it would point towards one of the four relay switch's which could be tied into a thermal issue since it worked after a few hours. In either case the interface would need to be brought here at Digidesign and diagnosed.

Brad