Quote:
Originally Posted by budda963
When its suggested that you gain stage your tracks to -18db rms, how are you measuring rms?
|
Not a lot of time right now but.....
When you hear -18dB, they're referring to peak dBFS, not RMS. That's because Pro Tools' default calibration is for -18dBFS to = +4dBu or 0dB VU which is of course the standard professional nominal operating level.