Quote:
Originally Posted by gus95
Sardi, you were completely right. Right clicking the level meters on the master fader solved the issue of the third photo.
Also, I noticed the levels on my AI were too low, and in addition, the output levels of my VI's were too high, causing the master fader to clip.
Thanks a lot for your time Sardi, TNM and YYR123
|
what i generally do is gain stage my VI's using the -18dbfs standard, by using the VI's output itself.. my mixer all at unity and everything hitting 0 using that measurement (an easy way to think about it is leaving 18db of headroom) and then i do my mix.
I use satson from sonimus.com to gain stage and often for my console emulation as well. Works a treat.
It's standard metering is -18.
Glad you got it fixed for now :)